Factory QC: How We Run Cycle Testing
Every soft-close batch passes automated cycle benches running 80,000 open-close repetitions before release.
Inspectors sample closing force at intervals of 10,000 cycles; any drift beyond tolerance triggers a full-batch hold and root-cause review.